GUARDMAN is a security system with high degree of reliability due to its state-of-art technology. Its sensors can be looped in any number to have security watch at any number of possible intrusion. It works on loop-breakage principle and hence works extremely satisfactorily even under worst practical conditions. It is compatible with all types of auto-dialer.
Lock Activate is the proprietory technique which positively checks up the closure of all outlets where sensors are fitted before the system is activated. False alarm is, thus a remote possibility.
WORKING PRINCIPLE:
GUARDMAN works on magnetic sensor principle. When magnetic loop is broken, while in
lock activated mode, it gives out a loud audio signal after a preset time delay. If the Panic Switch is pressed, siren is on continuously. At the same time, Auto Dialer, if installed, will also be activated. This can be disabled only by the user with the provided key.
GENERAL:
GUARDMAN works on regular mains supply of 230V, 50 Hz and switches over to battery during mains failure. Entire electronics is housed in a single PCB with proper connectors for interconnections. Imported sealed maintenance free battery inside the unit has uninterrupted working life of about three years. While on mains mode, battery is charged to its desired terminal voltage. All precautions are taken to avoid over charging of battery under continuous connection to mains. The unit contains battery and siren inside along with electronics.
|

SALIENT FEATURES
MAINS INPUT: 170-270 V, 50 Hz
BATTERY : 12 V, 4 Ah, SMF, UL-approved
BUILT-IN SIREN: Piezoelectric type
EXTERNAL SIREN: Piezoelectric type / other on request
PANIC SWITCH : Externally connected
AUTO DIALER : Optional (Add-on )
ENTER TIME DELAY : 2 Minutes
INDICATIONS : Six different LEDs
1. Mains On
2. System On
3. Enabled
4. Lockactivated
5. Intrusion
6. Siren On
CONTROL : System ON/OFF only by the user key.
LOCKACTIVATE : Proprietory feature of the system. When all doors/outlets are properly shut and the system is put on, a beep is given to indicate the closure of all doors and system is now ready to detect the intrusion. Unless all the concerned doors/windows are closed properly, the system will not be activated. This also eliminates any exit time delay as it is activated only when you make exit with doors closed.
|